Index: DamEngine/trunk/doc/Dam Engine - Functional Design/UseStabKernel.tex =================================================================== diff -u -r2396 -r2744 --- DamEngine/trunk/doc/Dam Engine - Functional Design/UseStabKernel.tex (.../UseStabKernel.tex) (revision 2396) +++ DamEngine/trunk/doc/Dam Engine - Functional Design/UseStabKernel.tex (.../UseStabKernel.tex) (revision 2744) @@ -50,23 +50,18 @@ \label{sec:TangentLinesGeneration} For the models Bishop and LiftVan a tangent lines must be generated. -There are two options: -\begin{enumerate} - \item automatic generation - \item client defined generation -\end{enumerate} -Ad 1 Automatic generation\newline -Bishop\newline --to described-\newline -Liftvan\newline --to described-\newline +Bishop: Automatic generation\newline +The tangent lines are placed from the minimum Z-value of the surface line until 0.5 m below the upper geometry point of the lowest aquifer. The distance between the tangent lines is 0.25 m. -Ad 2 Client defined\newline -For Bishop calcuations the tangent lines can not be defined by the client.\newline +LiftVan: Client defined\newline +Distance defined - Naar opgave afstand For LiftVan the client must provide the distance between the tangent lines. -The lower tangentline is always situated 5.0 m below the upper geometry point of the lowest aquifer. The tangentlines are drawn with the given distance until the upper tangent line is situated above the Z DikeToeAtPolder. +The lower tangentline is always situated 0.5 m below the upper geometry point of the lowest aquifer. The tangent lines are drawn with the given distance until the upper tangent line is situated above the Z DikeToeAtPolder. +On boundary - Op laagscheidingen +On every boundary of the subsoil layer below Z DikeToeAtPolder a tangent line is generated. + \subsection{Calculation area} \label{sec:CalculationArea} For the model Horizontal balance a calculation area must be defined: